SERVICE MANUAL
  Applies to: Hyundai Coupe/Tiburon 1998-2000
GROUP
Heating, Ventilation & Air Conditioning General
Return to Main Menu(s):      Mechanical Manual      Electrical Manual

SPECIFICATIONS 
Heater unit
Type
Three-way-flow-air-mix system
Heating capacity
4,500 ± 450 kcal/h

Heater control assembly: Rotary type (Vacuum Control System)

Air conditioning
Cooling capacity
4,100 ± 410 kcal/h
Compressor
Model
FX-15 (Switch plate type)
Refrigerant unit lubricant, cc (cu. in.)
PAG oil FD46XG or Equivalent 170-190cc (10.4-11.6)
Bore x stroke
29.0 mm x 23.3 mm
Displacement
154 cc/rev
Magnetic clutch
Voltage, power consumption
DC 12.8 ± 0.2V
Break away torque
Min. 40 Nm (400 kg.cm, 29.50 lb.in)
Coil resistance (12.8V at 20°C)
3.23 ± 0.08
Pressure relief valve (color: natural)
Working pressure
35.0 - 42.2 kg/cm2
(498-600 psi)
Resealed pressure
28.1 kg/cm2 (400 psi)
Dual pressure switch
High pressure switch
OFF 32 ± 2 kg/cm2
(3,140 kpa, 455 psi)

ON 26 ± 2 kg/cm2
(2,550 kpa, 370 psi)
Low pressure switch
OFF 2.0 ± 0.2 kg/cm2
(200 kpa, 28 psi)

ON 2.25 ± 0.2 kg/cm2
(220 kpa, 32 psi)
Freezer prevention
Electrical type (Thermistor)

OFF: 1.0 ± 1°C (33.8 ± 1.8°F)

ON: 4.0 ± 1°C (39.2 ± 1.8°F)

Refrigerant and quantity: R-134a Approx. 675-725g (1.50-1.61 lbs) Max.