Ground Floor Middle Floor Top Floor
Run   Boiler Kitchen Hall Downstairs Loo Lounge Conservatory Front Bedroom Rear Bedroom Bathroom Top Bedroom En Suite Dressing Room Max Min Diff
Info Flow R L (LSV) R (WH) L (LSV) L (LSV) R (TRV) R (TRV) R (TRV) R (TRV) L (LSV) L (LSV) R (TRV) - - -
Return L R (TRV) L (LSV) R (TRV) R (TRV) L (LSV) L (LSV) L (LSV) L (LSV) R (TRV) R (TRV) L (LSV) - - -
Height - 500 500 300 600 600 500 500 600 400 600 600 - - -
Length - 700 600 400 1000 600 1000 1000 500 700 500 600 - - -
Type - Double Double Single Single Double Single Single Double Double Single Single - - -
Output - 1048W 898W ~250W 948W 1041W 812W 812W 868W ~1000W 488W 570W - - -
LSV - Open Open Open Open Open Open Open Open Open Open Open - - -
1 LSV - All fully open (approx 3.5 turns depending on valve type/manufacturer) (=MAX) - - -
Flow 64.7 64.3 64.4 64.6 64.1 58.3 63.8 63.9 63.3 64.2 63.4 63.6 64.6 58.3 6.3
Return 56.3 54.3 58.7 62.3 54.3 51.8 58.1 57.9 57.9 57.4 60.2 60.4 62.3 51.8 10.5
Drop 8.4 10 5.7 2.3 9.8 6.5 5.7 6 5.4 6.8 3.2 3.2 10 2.3 7.7
Notes Boiler believed to be up to temperature (set at 3 out of 5 on an approximate scale of 30-82C). Burner modulating down low, not yet cycling.
2 LSV - All fully open (approx 3.5 turns depending on valve type/manufacturer) (=MAX) - - -
Flow 64.8 63.8 64.4 64.6 64.1 58.8 63.6 62.4 63.1 63.4 63.4 63.1 64.6 58.8 5.8
Return 57.4 54.3 58.3 62.1 54.1 51.8 58 57.4 57.7 56 59.8 60 62.1 51.8 10.3
Drop 7.4 9.5 6.1 2.5 10 7 5.6 5 5.4 7.4 3.6 3.1 10 2.5 7.5
Notes Run 2 performed 5 mins after Run 1 to check consistency in measurements/results and confirm system up to temperature. No changes to LSVs.
3 LSV - =MAX =MAX =1 =MAX =MAX =MAX =MAX =MAX =MAX =1.25 =1.25 - - -
Flow 65.8 65.2 65.4 65.8 64.4 59.6 64.4 63.3 63.4 64.4 64.3 64.3 65.8 59.6 6.2
Return 58.4 55.6 59.2 61.2 53.6 52.6 58.3 58.9 58.3 57.4 60.4 58.8 61.2 52.6 8.6
Drop 7.4 9.6 6.2 4.6 10.8 7 6.1 4.4 5.1 7 3.9 5.5 10.8 3.9 6.9
Notes LSV positions defined in number of turns open (from fully closed). System left to stabilise for 15mins before temperature readings taken.
4 LSV - =MAX =MAX =0.75 =MAX =MAX =MAX =MAX =MAX =MAX =0.75 =1 - - -
Flow 66.4 65.4 65.8 66 65.5 64.2 65 65.2 65.2 65.4 64.7 65 66 64.2 1.8
Return 58.3 55.8 59.6 62.6 56.1 54.1 59.7 59 60.8 58.2 60.4 60.7 62.6 54.1 8.5
Drop 8.1 9.6 6.2 3.4 9.4 10.1 5.3 6.2 4.4 7.2 4.3 4.3 10.1 3.4 6.7
Notes Small rads heading in the right direction but need to increase the middle floor drops.
5 LSV - =MAX =MAX =0.5 =MAX =MAX =1 =1 =1 =MAX =0.5 =0.75 - - -
Flow 66.7 64.9 66.4 65.5 65.7 64.4 65.8 65.4 65.6 65.8 65.4 65.5 66.4 64.4 2
Return 59.3 56.9 60.4 62.7 57.1 54.9 60.3 59.1 60.3 59.2 60.3 61.2 62.7 54.9 7.8
Drop 7.4 8 6 2.8 8.6 9.5 5.5 6.3 5.3 6.6 5.1 4.3 9.5 2.8 6.7
Notes Middle floor throttling has likely upped the flow elsewhere (hence drops on other rads also falling). Will try throttling all previously-throttled LSVs further (particularly so the d/stairs loo).
6 LSV - =MAX =MAX =0.25 =MAX =MAX =0.75 =1 =0.75 =MAX =0.25 =0.5 - - -
Flow 67.3 66.6 67.2 66.9 67.2 66.1 67.3 67.3 66.3 67.3 65.9 66.5 67.3 65.9 1.4
Return 59.4 58.5 62 61.2 59.1 57 60.8 61.6 61.2 61.1 55.5 62.1 62.1 55.5 6.6
Drop 7.9 8.1 5.2 5.7 8.1 9.1 6.5 5.7 5.1 6.2 10.4 4.4 10.4 4.4 6
Notes En suite is throttled too far. Dressing room, bathroom and hall need throttling a little bit further.
7 LSV - =MAX =1 =0.25 =MAX =MAX =0.75 =1 =2/3 =MAX =1/3 =1/3 - - -
Flow 67.4 67.1 67.8 67.2 67.4 66.4 67.2 67.6 67 67.4 66.9 66.8 67.8 66.4 1.4
Return 59.6 58.9 62 61.6 59.5 57.4 61.3 61.8 61.2 61.6 60.3 61.4 62 57.4 4.6
Drop 7.8 8.2 5.8 5.6 7.9 9 5.9 5.8 5.8 5.8 6.6 5.4 9 5.4 3.6
Notes Drop difference now within 3.6C (2.8C excluding conservatory radiator). Will try dropping pump speed (from 3 to 2) to see if all drops can be raised.
8 LSV - =MAX =1 =0.25 =MAX =MAX =0.75 =1 =2/3 =MAX =1/3 =1/3 - - -
Flow 68.3 68.3 68.6 67.7 68.3 67.2 67.3 68.1 67.7 68.1 67.2 67.2 68.6 67.2 1.4
Return 60.1 59.5 62.6 61.3 59.3 57.3 61.3 62 60.9 62 60.4 61.4 62.6 57.3 5.3
Drop 8.2 8.8 6 6.4 9 9.9 6 6.1 6.8 6.1 6.8 5.8 9.9 5.8 4.1
Notes Lowering pump speed didn't seem to do much difference (possibly upped the drop by nearly a degree?). Will try letting it stablise for longer…
8 LSV - =MAX =1 =0.25 =MAX =MAX =0.75 =1 =2/3 =MAX =1/3 =1/3 - - -
Flow 68.6 68.6 69 68.3 68.6 67.3 67.9 68.3 67.8 68.6 67.4 67.4 69 67.3 1.7
Return 60.5 59.9 62.8 62 59.6 57.6 61.8 62.3 60.4 62.1 60.5 62.2 62.8 57.6 5.2
Drop 8.1 8.7 6.2 6.3 9 9.7 6.1 6 7.4 6.5 6.9 5.2 9.7 5.2 4.5
Notes No change made to LSVs (system just left to stablise after dropping the pump speed from 3 to 2). Will try dropping to 1 for Run 9…
9 LSV - =MAX =1 =0.25 =MAX =MAX =0.75 =1 =2/3 =MAX =1/3 =1/3 - - -
Flow 69.6 69.3 69.9 69 69.3 67.9 68.6 69.3 68.2 69.4 68.3 68.5 69.9 67.9 2
Return 60.3 59.4 62.8 61.8 59.1 57.3 61.7 62.2 60.5 62.5 60.2 61.4 62.8 57.3 5.5
Drop 9.3 9.9 7.1 7.2 10.2 10.6 6.9 7.1 7.7 6.9 8.1 7.1 10.6 6.9 3.7
Notes Drops have now risen across the board (Ideal Icos manual says to have 11C drop max across boiler with all TRVs open). Will close top bedroom to 1 and tweak close other low-drop LSVs.
10 LSV - =MAX =1 =0.25 =MAX =MAX =0.75 =1 =2/3 =1 =1/3 =1/3 - - -
Flow 69.6 69.3 69.8 69 69.3 67.9 69.1 69.5 68.3 69.5 68.4 68.4 69.8 67.9 1.9
Return 59.6 59.3 62.8 61.8 59.4 57.4 61.9 62.4 60.9 61.4 60.4 60.1 62.8 57.4 5.4
Drop 10 10 7 7.2 9.9 10.5 7.2 7.1 7.4 8.1 8 8.3 10.5 7 3.5
Notes Listed LSV positions now approximate (following slight, immeasurable, tweaks). System balanced to within 3.5C (7C to 10.5C).