Using a cutter knife or the special tool, scrape the oil sealant smoothly to a thickness of about 2 mm on the bonding surface around the entire quarter fixed glass flange.
CAUTION
Be careful not to remove more adhesive than necessary, and also not to damage the paintwork on the body surface with the knife. If the paintwork is damaged, repair the damaged area with touch-up paint.
Clean the body flange surface of quarter fixed glass aperture with a sponge dampened in solvent.
Clean completely the contaminants such as oil and dust in the primer-applied part of body aperture.
After cleaning body aperture flange surface, pass a minute or more then, apply the primer to body.
Apply the primer to body flange surface of quarter fixed glass.
To use the primer, shake the vessel ten minutes or more.
Apply a primer to the glass and the glass moulding assembly.
Apply the sealant to the entire circumference of the glass.
NOTE
Install the glass to the body within five minutes.
Install the mounting screws from the quarter fixed glass.
Installation of each of the trim parts is the reverse of the removal procedure.